UCLA Researchers & Innovators
Industry & Investors
News & Events
About
Concierge
Search Results - glen+meyerowitz
2
Results
Sort By:
Published Date
Updated Date
Title
ID
Descending
Ascending
2020-810 Mechanical Ventilator With a Fixed Number of Orifice Plates to Generate Constant Flow Paths
Summary: UCLA researchers in the Department of Electrical and Computer Engineering & Bioengineering have developed a constant flow path mechanical ventilator used for the treatment of advanced respiratory diseases, such as acute respiratory distress syndrome (ARDS). Background: Respiratory failure leading to the need for respiratory support...
Published: 2/14/2025
|
Inventor(s):
Glen Meyerowitz
Keywords(s):
Angiogenesis Acute Lung Injury
,
Cellular Respiration
,
Cerebrospinal Fluid
,
Cerebrospinal Fluid Tetramer Retinol Binding Protein
,
Cerebrospinal Fluid Ventricular System Bleeding
,
Deoxygenation
,
Diagnostic Markers & Platforms
,
Diagnostic Platform Technologies (E.G. Microfluidics)
,
Diagnostic Test
,
Digital Microfluidics
,
Ferrofluid
,
Flow Device
,
Fluid Dynamics
,
Fluidics
,
Half-Reaction Electrolysis Of Water Oxygen Evolution
,
Intensive-Care Unit Vital Signs
,
Lung
,
Lung Pulmonology
,
Mechanical
,
Mechanical Engineering
,
Mechanical Systems
,
Medical Device
,
Medical Device Poly(Methyl Methacrylate)
,
Medical Devices and Materials
,
Microfluidics
,
Microfluidics And Mem's
,
Microfluidics Dielectrophoresis
,
Microfluidics Multi-Band Device
,
Microfluidics Nanosphere
,
Mouse Respiratory System
,
Oxygen
,
Oxygen Saturation
,
Reactive Oxygen Species
,
Respiratory & Pulmonary
,
Synovial Fluid
Category(s):
Mechanical
,
Mechanical > Mechanical Systems
,
Therapeutics > Infectious Diseases > COVID
Flow Regulation Mechanism for Compartmentalized Lung Ventilation (Case No. 2021-092)
Summary: UCLA researchers in the Department of Pulmonary and Clinical Care have developed a device capable of analyzing individual lungs in real-time to improve the quality of care for mechanically ventilated patients. Background: Ventilators aid patients that have difficulty breathing by pressing positive air pressure into their lungs. Mechanical...
Published: 6/9/2025
|
Inventor(s):
Igor Barjaktarevic
,
Glen Meyerowitz
Keywords(s):
Angiogenesis Acute Lung Injury
,
Diagnostic Test
,
Drug Delivery
,
Instrumentation
,
Lung
,
Lung Pulmonology
,
Medical Device
,
Medical Imaging
,
Monitoring And Recording Systems
,
Respiratory & Pulmonary
,
Sensors
,
Software
Category(s):
Medical Devices
,
Medical Devices > Medical Imaging
,
Medical Devices > Monitoring And Recording Systems
,
Therapeutics > Infectious Diseases > COVID
,
Therapeutics > Respiratory And Pulmonary
,
Software & Algorithms > Programs